PowerScan™D8330/M8300USER MANUALSeptember 23, 2011PN 8000166.BISO 9001 CertifiedQuality Management System

Strany 2 - Disclaimer

POWERSCAN™ D8330/M8300 iv 6.2.5 Setting RTC ...

Strany 3 - Return to Factory Warranty

88 DECODING PARAMETERS  Ink Spread Overflow Control Interdigit Control Decoding Safety Puzzle Solver™ Before changing these paramet

Strany 4 - What is RoHS?

Enter Configuration Exit and Save Ì$+;Î DECODING PARAMETERS Ì$-?Î 89 INK SPREAD disable ÌAX0{Î  enable ÌAX1~Î See section 5.7.1 for details.

Strany 5 - Worldwide Offices

Enter Configuration Exit and Save Ì$+;Î DECODING PARAMETERS Ì$-?Î 90 DECODING SAFETY  one read ÌED0WÎ (decoding safety disabled) two reads

Strany 6

91 CODE SELECTION  Auto-configuration EAN/UPC Family 2/5 Family Code 39 Family Code 128 Family Codabar Family Code 93 MSI Code 11

Strany 7 - CONTENTS

92 Code selections may be performed according to two different procedures: - Auto-configuration, allowing an automatic recognition and selection o

Strany 8

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 93 DISABLE ALL CODE FAMILIES ÌAZ0ÃÎ The reader allows up to 10 code selections. T

Strany 9 - TABLE OF CONTENTS

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 94 EAN/UPC FAMILY disable the family ÌAA0MÎ  Read the desired family code NOTE

Strany 10

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 95 WITH ADD ON 2 ONLY EAN 8/EAN 13 ÌAAK7Î UPC A/UPC E ÌAAM=Î WITH ADD ON 5 ONLY

Strany 11 - GENERAL VIEW

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 96 SELECT EAN/UPC PREFIXES When scanning the following codes, barcodes starting wi

Strany 12

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 97 Example: The following string allows reading and transmitting with ADD ON all EAN/U

Strany 13 - 1 INTRODUCTION

GENERAL VIEW v GENERAL VIEW POWERSCAN™ D8330/M8300 READERS Figure A – PowerScan™ D8330/M8300 Series Reader Figure B – PowerScan™ M8300 Seri

Strany 14 - 2 INSTALLATION

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 98 EAN/UPC CHECK DIGIT TX SELECTIONS For each code type in this family you can choo

Strany 15

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 99 CONVERSION OPTIONS UPC E to UPC A conversion ÌAAAÄÎ UPC E to EAN 13 conversion

Strany 16

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 100 2/5 FAMILY disable the family ÌAC0QÎ  Read the desired family code  R

Strany 17 - 2.4 USB

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 101 CODE 39 FAMILY disables the family ÌAB0OÎ  Read the desired family code 

Strany 18 - 2.5 IBM USB POS

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 102 CODE 128 FAMILY disable the family ÌAI0]Î  Read the desired family code 

Strany 19 - 2.6 WEDGE CONNECTION

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 103 CODE 93  disable the code ÌAK0aÎ Code 93 ÌAK1dÎ control without transmission

Strany 20 - 2.8 NETWORK CONNECTIONS

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 104 The Codabar ABC code below uses a fixed start/stop character transmission selec

Strany 21 - 2.8.2 Network Cabling

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 105 MSI  disable the family ÌAE0UÎ Enable the code by selecting one of the check di

Strany 22 - 2.8.3 Network Termination

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 106 CODE 11  disable the family ÌAG0YÎ Enable the code by selecting one of the ch

Strany 23 - M8300 Batteries

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 107 CODE 16K  disable the code ÌAJ0_Î Code 16K ÌAJ1bÎ To read stacked codes, si

Strany 24

POWERSCAN™ D8330/M8300 vi BC-80X0 / C-8000 CRADLES Figure C – BC-8000 The label on the cradle contains LED indicators and a scan finder button. Wh

Strany 25 - 2.10.1 Desktop Mounting

Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 108 GS1 DATABAR™ CODES  disable the family ÌAQ0mÎ DISABLE CODE disable GS1 DataB

Strany 26 - Fixed Desktop Use

109 ADVANCED FORMATTING NOT FOR PEN INTERFACES  Concatenation Advanced Formatting Please follow the setup procedure carefully for these

Strany 27 - INSTALLATION

Enter Configuration Exit and Save Ì$+;Î ADVANCED FORMATTING Ì$-?Î 110 CONCATENATION  disable ÌEI0aÎ enable ÌEI1dÎ Permits the concatenati

Strany 28 - 2.10.2 Wall Mounting

Exit and Save ADVANCED FORMATTING Ì$-?Î 111 2 Code 2 code ID  ÌEK1hÎ Read the code type from the Code Identifier Table beginning in Appen

Strany 29 - Inclined Base Wall-mounting

Exit and Save ADVANCED FORMATTING Ì$-?Î 112 5 Transmission after Timeout no code transmitted after timeout ÌEM0iÎ only code 1 tran

Strany 30 - LAYOUTS

ADVANCED FORMATTING 113 ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of b

Strany 31

Enter Configuration Exit and Save Ì$+;Î ADVANCED FORMATTING Ì$-?Î 114 1 Begin Format Definition begin Format 1 definition  ÌHA0TÎ be

Strany 32 - 3.1.4 C-BOX Layout

Exit and Save ADVANCED FORMATTING Ì$-?Î 115 4 Match with Predefined Characters no match ÌHD0HE00ÄÎ OR match with 1 character  ÌH

Strany 33 - 3.2.1 Host Master Layout

Exit and Save ADVANCED FORMATTING Ì$-?Î 116 5 Divide Code into Fields divide code into fields  ÌHF.Î Read one number in the range 1

Strany 34 - 3.2.2 BC-8060 Master Layout

Exit and Save ADVANCED FORMATTING Ì$-?Î 117 DEFINE FIELD 1 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX

Strany 35 - Example:

INTRODUCTION 1 1 INTRODUCTION PowerScan™ D8330 and PowerScan™ M8300 offer unsurpassed robustness and ergonomics: clearly audible beeper and bri

Strany 36 - 4 CONFIGURATION

Exit and Save ADVANCED FORMATTING Ì$-?Î 118 DEFINE FIELD 2 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the H

Strany 37 - 4.2 SETUP PROCEDURES

Exit and Save ADVANCED FORMATTING Ì$-?Î 119 DEFINE FIELD 3 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX

Strany 38 - Ì$+$*oÎ

Exit and Save ADVANCED FORMATTING Ì$-?Î 120 DEFINE FIELD 4 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the H

Strany 39 - 4.5 POWERSCAN

Exit and Save ADVANCED FORMATTING Ì$-?Î 121 DEFINE FIELD 5 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX

Strany 40 - Ì$+RX0$-qÎ

Exit and Save ADVANCED FORMATTING Ì$-?Î 122 7 First Additional Fixed Field no fixed field ÌHI0dÎ 1 character fixed field  ÌHI

Strany 41 - Ì$+RN1$-NÎ

Exit and Save ADVANCED FORMATTING Ì$-?Î 123 8 Second Additional Fixed Field no fixed field ÌHJ0fÎ 1 character fixed field  ÌHJ1

Strany 42 - 4.5.2 PowerScan

Exit and Save ADVANCED FORMATTING Ì$-?Î 124 9 Field Transmission number of fields to transmit ÌHK8Î Read one number in the range 1

Strany 43 - M8300/STAR-SYSTEM™ SETUP

Exit and Save ADVANCED FORMATTING Ì$-?Î 125 10 Standard Formatting do not apply standard formatting ÌHL0jÎ apply stand

Strany 44

Enter Configuration Exit and Save Ì$+;Î ADVANCED FORMATTING Ì$-?Î 126 Enable Advanced Format  no Advanced Formats enabled ÌHN0nÎ Advan

Strany 45 - Ì$+RF4Î

Enter Configuration Exit and Save Ì$+;Î ADVANCED FORMATTING Ì$-?Î 127 No Match Result clear data - no transmission ÌHO0pÎ transmit data using sta

Strany 46 - Ì$+RZ1$-~Î

POWERSCAN™ D8330/M8300 2 2 INSTALLATION Connections should always be made with power OFF! CAUTION 2.1 POWERSCAN™ D8330 INTERFACE CABLE CONN

Strany 47 - Ì$+CP6$-BÎ

128 RADIO PARAMETERS PowerScan™ M8300 Series readers only  Radio Protocol Timeout Radio RX Timeout Power-Off Timeout  Transmission Mode

Strany 48

Enter Configuration Exit and Save Ì$+;Î RADIO PARAMETERS Ì$-?Î 129 RADIO PROTOCOL TIMEOUT radio protocol timeout  ÌRH<Î Read a number from t

Strany 49

Enter Configuration Exit and Save Ì$+;Î RADIO PARAMETERS Ì$-?Î 130 POWER-OFF TIMEOUT power-off timeout  ÌRPLÎ Read 2 numbers in the range 00-99

Strany 50 - First Start-Up

Enter Configuration Exit and Save Ì$+;Î RADIO PARAMETERS Ì$-?Î 131 BEEPER CONTROL FOR RADIO RESPONSE  normal ÌBF0XÎ only good decode on

Strany 51

Enter Configuration Exit and Save Ì$+;Î RADIO PARAMETERS Ì$-?Î 132 SINGLE STORE  disable ÌRO0zÎ one attempt two attempts ÌRO1}Î ÌRO2ÄÎ

Strany 52

Enter Configuration Exit and Save Ì$+;Î RADIO PARAMETERS Ì$-?Î 133 BATCH MODE  disable batch ÌBZ0ÄÎ enable automatic batch enable normal

Strany 53 - RS-232 PARAMETERS

134 DISPLAY AND KEYPAD PARAMETERS PowerScan™ M8300 Series Display and 3-Key readers only  Date and Time Contrast Font Size Backlight

Strany 54 - BAUD RATE

Enter Configuration Exit and Save Ì$+;Î DISPLAY PARAMETERS Ì$-?Î 135 DISPLAY PARAMETERS DATE AND TIME set date  ÌIA%Î set time Read 6 nu

Strany 55 - HANDSHAKING

Enter Configuration Exit and Save Ì$+;Î KEYPAD PARAMETERS Ì$-?Î 136 DISPLAY-OFF TIMEOUT timeout ÌIF/Î Read 2 numbers in the range 00-99: 00 = d

Strany 56 - INTER-CHARACTER DELAY

Enter Configuration Exit and Save Ì$+;Î DISPLAY PARAMETERS Ì$-?Î 137 KEYPAD disable 3-key keypad ÌIK0iÎ  enable 3-key keypad and select ch

Strany 57 - SERIAL TRIGGER LOCK

INSTALLATION 3 Follow the given procedure for correct cable insertion:  Slip the cover over the cable.  Push the plastic boot into the rubbe

Strany 58 - USB PARAMETERS

POWERSCAN™ D8330/M8300 138 5 REFERENCES 5.1 RS-232 PARAMETERS 5.1.1 Handshaking Hardware handshaking: (RTS/CTS) The RTS line is activated by

Strany 59

REFERENCES 139 5.1.2 ACK/NACK Protocol PowerScan™ D8330 Readers This parameter sets a transmission protocol in which the Host responds to the reade

Strany 60

POWERSCAN™ D8330/M8300 140 BC-80X0 Host datacable PowerScan® M8300 data NACK ACKgood RX beep Transmission Mode = Two-Waysdata ACK/NACK enabled

Strany 61 - KEYBOARD NATIONALITY

REFERENCES 141 5.1.4 RX Timeout When the RS-232 interface is selected, the Host can be used to configure the device by sending it command strings (

Strany 62

POWERSCAN™ D8330/M8300 142 5.2.3 Overflow This parameter generates a white space before the first bar and after the last bar of the code. The selec

Strany 63 - USB KEYBOARD SPEED

REFERENCES 143 5.2.5 Inter-Block Delay For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20 characters each. The i

Strany 64 - WEDGE PARAMETERS

POWERSCAN™ D8330/M8300 144 The message is sent in the following format: "Message" CR LF 5.3.3 Reception Warning Message The Master cra

Strany 65

REFERENCES 145 5.4 DATA FORMAT For an overview of Message Formatting see Chapter 6. 5.4.1 Header/Terminator Selection The header/terminator sele

Strany 66 - CAPS LOCK

Enter Configuration Exit and Save Ì$+;Î Ì$-?Î 146 5.4.2 Define Special Key Sequence The Special Key(s) for Wedge IBM AT-PS/2 and USB-KBD interfa

Strany 67 - NUM LOCK

REFERENCES 147 2. Read only one code to be associated with the special key sequence: SHIFT Ì12Î OR CTRL Ì23Î OR ALT Ì45Î

Strany 68 - KEYBOARD SETTING

POWERSCAN™ D8330/M8300 4 2.2 BC-80X0 INTERFACE CABLE CONNECTIONS BC-80X0 Connectors The BC-80X0 incorporates a multi-standard interface, whi

Strany 69 - CONTROL CHARACTER EMULATION

POWERSCAN™ D8330/M8300 148 3. Select the character to be associated with the Special Key sequence by reading the codes corresponding to the 3 charac

Strany 70 - PEN EMULATION

REFERENCES 149 ITA USA FR BE DE UK ES SW JP : 049 S 04C S049 049 049 S04C S049 S049 S 052 ; 041 S 04C 041 041 041 S04C 041 S041 S 04C < 061

Strany 71 - OPERATING MODE

POWERSCAN™ D8330/M8300 150 ITA USA FR BE DE UK ES SW JP w 01D 01D 01A 01A 01D 01D 01D 01D 01D x 022 022 022 022 022 022 022 022 022 y 035 035

Strany 72 - MINIMUM OUTPUT PULSE

REFERENCES 151 ITA USA FR BE DE UK ES SW JP Up arrow 275 275 275 275 275 275 275 275 275 Down arrow 272 272 272 272 272 272 272 272 272 Left

Strany 73 - OVERFLOW

POWERSCAN™ D8330/M8300 152 2. The following example allows defining Special Key 2 as CTRL + S (uppercase): enter configuration define Special

Strany 74 - INTER-BLOCK DELAY

REFERENCES 153 - Integrating Special Keys in Headers/Terminators - 1. The following example allows setting Special Key 1 (defined in example 1 abo

Strany 75 - NETWORK PARAMETERS

POWERSCAN™ D8330/M8300 154 5.4.3 Address Stamping It is possible to include the reader address in the message sent to the host. The Reader Address

Strany 76 - NETWORK BAUD RATE

REFERENCES 155 5.5 POWER SAVE 5.5.1 Sleep State When using interfaces other than USB, this mode allows the P in the reader to enter a “Sleep” s

Strany 77 - RECEPTION WARNING MESSAGE

POWERSCAN™ D8330/M8300 156 5.6 READING PARAMETERS 5.6.1 Trigger Signal This mode determines how the reading phase is controlled when the hardware

Strany 78 - MASTER CRADLE HEADER

REFERENCES 157 In multiple reads per cycle, the ON period is extended so that the device can continue decoding codes until an OFF event occurs. For

Strany 79 - MASTER CRADLE TERMINATOR

INSTALLATION 5 2.3 RS-232 CONNECTION 2.4 USB (if required)

Strany 80 - DATA FORMAT

POWERSCAN™ D8330/M8300 158 5.7.3 Interdigit Control The interdigit control parameter verifies the interdigit spacing for code families Code 39 and

Strany 81 - DATA FORMAT

REFERENCES 159 5.9.2 Radio RX Timeout When the scanner is used in a standalone layout (point-to-point or with multiple readers) it can be configu

Strany 82 - CUSTOM CODE IDENTIFIER

POWERSCAN™ D8330/M8300 160 5.9.4 Transmission Mode This parameter determines whether the reader receives responses or messages from the Host or not

Strany 83 - four character header

REFERENCES 161 5.9.6 Single Store When single store mode is enabled, if the PowerScan™ M8300 fails to transmit a code to the cradle, it enters a s

Strany 84 - TERMINATOR

POWERSCAN™ D8330/M8300 162 returns in range, transmission of the codes to the base station resumes automatically, according to the selected communica

Strany 85 - SPECIAL KEYS

REFERENCES 163 5.10 DISPLAY PARAMETERS (SOME M8300 MODELS ONLY) 5.10.1 Display Mode The user can control the reader display behavior according

Strany 86 - FIELD ADJUSTMENT

POWERSCAN™ D8330/M8300 164 5.11 CONFIGURATION EDITING COMMANDS The following commands carry out their specific function and then exit the configura

Strany 87 - CODE LENGTH TX

REFERENCES 165 5.12 CUSTOM DEFAULT CONFIGURATION Read the following code to set the reader user-defined configuration as custom default configurat

Strany 88 - CHARACTER REPLACEMENT

POWERSCAN™ D8330/M8300 166 5.14 CONFIGURATION COPYING COMMANDS 5.14.1 Copy PowerScan D8330 Series Procedure:  Connect the master (correctly con

Strany 89 - Code 39 barcodes

REFERENCES 167 5.14.2 Copy PowerScan M8300 Series Procedure:  Using the slave reader and its BC-80X0 cradle, follow the initialization procedure

Strany 90

POWERSCAN™ D8330/M8300 6 2.5 IBM USB POS (if required)

Strany 91 -

POWERSCAN™ D8330/M8300 168 5.14.3 Copy BC-80X0 Procedure:  Using the slave reader and its BC-80X0 cradle, read the Restore Default barcode, set th

Strany 92

REFERENCES 169 5.15 DEFAULT PARAMETERS FOR POS TERMINALS The default values of the RS-232 and Data Format parameters for POS terminals are listed

Strany 93 - ENTER SLEEP TIMEOUT

POWERSCAN™ D8330/M8300 170 5.16 FIRMWARE UPGRADE Device firmware upgrades can be performed from your PC through either a USB or serial connection (

Strany 94

MESSAGE FORMATTING 171 6 MESSAGE FORMATTING 6.1 STANDARD MESSAGE FORMATTING The system always provides scanner to host data communication using

Strany 95 - TRIGGER CLICK

POWERSCAN™ D8330/M8300 172 6.2 MESSAGES FROM HOST TO READER The general format to enable the Scanner for a 2 way communication is: [Scanner_Addr]

Strany 96 - READS PER CYCLE

MESSAGE FORMATTING 173 6.2.1 Cursor Control ESC [ n AUp n rows, no scrollESC [ n BDown n rows, no scrollESC [ n CRight n columnsESC [ n DLeft n co

Strany 97 - BEEPER INTENSITY

POWERSCAN™ D8330/M8300 174 6.2.4 LED and Beeper Control ESC [ 0 q Emit short High tone + short delayESC [ 1 q Emit short Low tone + short delayES

Strany 98 - BEEPER LENGTH

MESSAGE FORMATTING 175 6.3 MESSAGES FROM SCANNER COMMAND KEYS 6.3.1 PowerScan M8300 keypad The PowerScan™ M8300 series scanners with display hav

Strany 99 - CRADLE BEEPER INTENSITY

POWERSCAN™ D8330/M8300 176 7 TECHNICAL FEATURES 7.1 POWERSCAN™ D8330 Electrical Features POWERSCAN™ D8330 POWERSCAN™ D8330 AR Power Supply 4 to

Strany 100 - DECODING PARAMETERS

TECHNICAL FEATURES 177 7.2 POWERSCAN™ M8300 Electrical and General Features Battery Type 2150 Li-Ion battery pack Recharge Time max. 4 hours with

Strany 101 - INTERDIGIT CONTROL

INSTALLATION 7 2.6 WEDGE CONNECTION 2.7 PEN EMULATION CONNECTION

Strany 102 - PUZZLE SOLVER™

POWERSCAN™ D8330/M8300 178 7.3 BC-80X0 / C-8000 Electrical and General Features Supply Voltage External Power 10 to 30 VDC Host Power 5 VDC

Strany 103 - CODE SELECTION

TECHNICAL FEATURES 179 7.4 SYSTEM AND RADIO FEATURES Radio Features European Models USA Models Radio Frequency 433.92 MHz 910 MHz Bit Rate 192

Strany 104 - Ì#+AUTOWÎ

POWERSCAN™ D8330/M8300 180 POWERSCAN™ D8330/M8300 READER DATA ENTRY Beeper1 LED Good Read Spot Meaningone beep2 ON ON Correct read of a code in no

Strany 105 - DISABLE ALL CODE FAMILIES

TECHNICAL FEATURES 181 BC-80X0/C-8000 POWER/COMMUNICATION Aux LED Host LED Meaning Yellow Yellow OFF OFF Device off ON Power applied through an

Strany 106 - WITH ADD ON 2 AND 5

POWERSCAN™ D8330/M8300 182 7.6 Reading Tables POWERSCAN™ D8330/M8300 mil Typical reading distance with good quality codes 5 2.1 - 13.3 cm / 0.8

Strany 107 - Exit and Save

HOST CONFIGURATION STRINGS 183 A HOST CONFIGURATION STRINGS In this section we provide a description of how to modify the device configuration usin

Strany 108 - SELECT EAN/UPC PREFIXES

POWERSCAN™ D8330/M8300 184 SERIAL CONFIGURATION STRINGS SPECIAL CONFIGURATION COMMANDS DESCRIPTION STRING Enter Configuration $+ Exit and Save Conf

Strany 109 - 434/439:

HOST CONFIGURATION STRINGS 185 RS-232DESCRIPTION STRING Baud Rate 300 CD1 600 CD2 1200 CD3 2400 CD4 4800 CD5 9600 CD6 19200 CD7 38400

Strany 110

POWERSCAN™ D8330/M8300 186 USBDESCRIPTION STRING USB-COM Handshaking disable CE0 RTS/CTS CE1 XON/XOFF CE2 RTS always ON CE3 ACK/NACK Protoc

Strany 111 - CONVERSION OPTIONS

HOST CONFIGURATION STRINGS 187 WEDGEDESCRIPTION STRING Keyboard Nationality Belgian FJ7 English (UK) FJ4 French FJ2 German FJ3 Italian FJ1

Strany 112 - 2/5 FAMILY

© Copyright 2011 by Psion Inc.2100 Meadowvale BoulevardMississauga, Ontario, Canada L5N 7J9http://www.psion.comThis document and the information it co

Strany 113 - CODE LENGTH (OPTION

POWERSCAN™ D8330/M8300 8 2.8 NETWORK CONNECTIONS 2.8.1 BC-8060 Network Connectors The multidrop network is a bus system which is propagated f

Strany 114

POWERSCAN™ D8330/M8300 188 PEN (continued)DESCRIPTION STRING Output Level normal DD0 inverted DD1 Idle Level normal DE0 inverted DE1 Overflo

Strany 115 - CODABAR FAMILY

HOST CONFIGURATION STRINGS 189 DATA FORMATNOT FOR PEN EMULATION INTERFACES DESCRIPTION STRING Code Identifier disable EB0 Manufacturer standard E

Strany 116

POWERSCAN™ D8330/M8300 190 DATA FORMAT (continued)NOT FOR PEN EMULATION INTERFACESDESCRIPTION STRING Code Length Tx not transmitted EE0 transmi

Strany 117

HOST CONFIGURATION STRINGS 191 POWER SAVEDESCRIPTION STRING Sleep State disable BQ0 (only for D8330 series) enable BQ1 Enter Sleep Timeout (10

Strany 118 - CODE 11

POWERSCAN™ D8330/M8300 192 DECODING PARAMETERSDESCRIPTION STRING Ink-spread disable AX0 enable AX1 Overflow Control disable AW1 enable AW0 In

Strany 119 - CODE 49

HOST CONFIGURATION STRINGS 193 CODE SELECTION (continued) DESCRIPTION STRING UPC A check digit transmission disable AAI0 enable AAI1 UPC

Strany 120 - GS1 DATABAR™ CODES

POWERSCAN™ D8330/M8300 194 CODE SELECTION (continued)DESCRIPTION STRING Codabar disable Codabar family AD0 Standard no start/stop character eq

Strany 121 - ADVANCED FORMATTING

HOST CONFIGURATION STRINGS 195 CODE SELECTION (continued)DESCRIPTION STRING Code 11 disable the family AG0 no check AG1 Type C with tx AG2

Strany 122 - CONCATENATION

POWERSCAN™ D8330/M8300 196 DISPLAY PARAMETERSDESCRIPTION STRING Date IAddmmyy Time IBhhmm Contrast lighter IC0 darker IC1 Font Size small ID0

Strany 123

CODE IDENTIFIER TABLE 197 B CODE IDENTIFIER TABLE 2/5 Interleaved ÌNOÎ 2/5 Industrial 2/5 normal 5 bars ÌPQÎ ÌOPÎ 2/5 matrix 3 bars EAN 8 ÌQRÎ ÌA

Strany 124

INSTALLATION 9 2.8.2 Network Cabling The Multidrop line is made using RJ45 connectors and a cable having the following specifications:  twisted

Strany 125

POWERSCAN™ D8330/M8300 198 UPC A with 5 ADD ON ÌGHÎ UPC E with 2 ADD ON UPC E with 5 ADD ON ÌHIÎ ÌIJÎ Code 39 Code 39 Full ASCII ÌVWÎ ÌWXÎ CODABAR AB

Strany 126

CODE IDENTIFIER TABLE 199 MSI ÌZ[Î Code 16K Code 11 ÌpqÎ ÌbcÎ Code 49 GS1 DATABAR Expanded Linear and Stacked ÌqrÎ ÌtuÎ GS1 DATABAR Limited GS1 DAT

Strany 127

POWERSCAN™ D8330/M8300 200 C HEX AND NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLEchar hex char hex char hex NUL 00 * 2A U 55 SOH 01 + 2

Strany 128

CODE IDENTIFIER TABLE 201 CHARACTER TO HEX CONVERSION TABLE (continued)char decimal hex char decimal hex char decimal hex € 128 80 ª 170 AA Õ 21

Strany 129

POWERSCAN™ D8330/M8300 202 HEX/NUMERIC BAR CODES 0 1 2 3 4 5 6 7 8 9

Strany 130

CODE IDENTIFIER TABLE 203 A B C D E F Backspace

Strany 132

POWERSCAN™ D8330/M8300 10 2.8.3 Network Termination The first and last cradles of the chain (the two ends of the bus) must be properly terminate

Strany 133

INSTALLATION 11 2.9 POWERSCAN™ M8300 BATTERY MAINTENANCE 2.9.1 Battery Charging Once the system is connected and powered, you can place the Powe

Strany 134 - 4 Character Fixed Field

POWERSCAN™ D8330/M8300 12 2.10 MOUNTING THE BC-80X0 / C-8000 CRADLE The cradle package contains the following items:  BC-80X0 / C-8000 Cradle

Strany 135 - 3 Character Fixed Field

INSTALLATION 13 2.10.1 Desktop Mounting For desktop usage, you can mount the cradle either on the horizontal base, for reduced overall dimensions,

Strany 136

POWERSCAN™ D8330/M8300 14 Portable Desktop Use 1. Correctly position the BC-80X0/C-8000 onto the base by sliding it along the mounting tabs unti

Strany 137

INSTALLATION 15 Horizontal Base Inclined Base 5. Remove the plastic from the other

Strany 138

POWERSCAN™ D8330/M8300 16 2.10.2 Wall Mounting 1. Remove the yellow caps and insert the two wall mounting lock hinges provided with your cradle

Strany 139

INSTALLATION 17 If using the adhesive strips: 3. Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce a

Strany 140 - RADIO PARAMETERS

Return to Factory WarrantyPsion provides a return to factory warranty on this product for aperiod of twelve (12) months in accordance with the stateme

Strany 141 - RADIO RX TIMEOUT

POWERSCAN™ D8330/M8300 18 3 POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS There are two basic system layouts that can be employed: Stand-alone sys

Strany 142 - TRANSMISSION MODE

POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS 19 3.1.3 Multiple Stand-Alone Layouts Many stand-alone connections can operate in the same physical a

Strany 143

POWERSCAN™ D8330/M8300 20 3.1.4 C-BOX Layout In this layout the BC-80X0 cradle is connected by a dedicated cable using the RS-232 interface t

Strany 144 - SINGLE STORE

POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS 21 3.2 MULTIDROP STAR-SYSTEM™ NETWORK LAYOUTS Even though many stand-alone systems can operate in the

Strany 145 - FIND ME

POWERSCAN™ D8330/M8300 22 3.2.2 BC-8060 Master Layout A. Host B. BC-8060 Master cradleC. BC-8060 Slave cradlesD. STARGATE™ base stationExampl

Strany 146 - PARAMETERS

POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS 23 3.2.3 Master BC-8060 Network Troubleshooting Two diagnostic strings can be sent via RS-232 from th

Strany 147 - DISPLAY PARAMETERS

POWERSCAN™ D8330/M8300 24 4 CONFIGURATION 4.1 CONFIGURATION METHODS 4.1.1 Reading Configuration Barcodes This manual can be used for complete

Strany 148 - DISPLAY MODE

CONFIGURATION 25 4.1.4 Sending Configuration Strings from Host An alternative configuration method is provided in Appendix A using the RS-232 inter

Strany 149

POWERSCAN™ D8330/M8300 26 4.3 POWERSCAN™ D8330 SETUP 1. Read the restore default parameters code below. Restore PowerScan™ D8330 Default Ì$+$*oÎ

Strany 150 - 5 REFERENCES

CONFIGURATION 27 4.5 POWERSCAN™ M8300/BC-80X0 STAND-ALONE SETUP Read the restore default parameters code below. 1. Restore PowerScan™ M8300 Def

Strany 151 - 5.1.2 ACK/NACK Protocol

Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC & Waste Batteries Directive 2006/66/ECThis Product, and its accessories, com

Strany 152 - 5.1.3 FIFO

POWERSCAN™ D8330/M8300 28 7. Read the Bind code to pair the PowerScan™M8300 to the BC-80X0 cradle. The reader is dedicated to the cradle. Any previou

Strany 153 - 5.2.1 Minimum Output Pulse

CONFIGURATION 29 4.5.1 Using Multiple M-Series Readers with the Same Cradle If you want to use several M-Series readers with the same BC-80X0 crad

Strany 154 - 5.2.3 Overflow

POWERSCAN™ D8330/M8300 30 4.5.2 PowerScan™ M8300/STAR-Modem™ in Stand-Alone Mode To configure a PowerScan™ M8300 reader to communicate with STAR-Mo

Strany 155 - 5.3 NETWORK PARAMETERS

CONFIGURATION 31 4.6 POWERSCAN™ M8300/STAR-SYSTEM™ SETUP The following procedure allows configuring a PowerScan™ M8300 reader to communicate with

Strany 156

POWERSCAN™ D8330/M8300 32 6. Set Radio Address ÌRF8Î + four digits from the Numeric Table in the range 0000-1999. ALL READERS MUST HAVE DIFFERENT

Strany 157 - 5.4 DATA FORMAT

CONFIGURATION 33 4.7 BC-8060 STAR-SYSTEM™ NETWORK SETUP When the BC-8060 cradle model is used in an RS-485 network, it must be initially configure

Strany 158

POWERSCAN™ D8330/M8300 34 5. Read the BC-8060 restore default code: Restore BC-8060 Default Ì$+RX0$-qÎ 6. Read the desired Enable Network code

Strany 159

CONFIGURATION 35 4.8 INTERFACE SELECTION Read the interface selection code for your application. RS-232 Standard Ì$+CP0$-$Î POS TERMINALS

Strany 160 - POWERSCAN™ D8330/M8300

POWERSCAN™ D8330/M8300 36 WEDGE IBM AT or PS/2 PCs Ì$+CP500$-aÎ IBM XT PC Notebook Ì$+CP503$-vÎ Ì$+CP505$-ÈÎ IBM SURE1 IBM Terminal 3153

Strany 161 - REFERENCES

CONFIGURATION 37 WEDGE (CONTINUED) ALT MODE The ALT-mode selection allows barcodes sent to the PC to be interpreted correctly independently from t

Strany 162

Technical SupportFor technical support in North America:Call Toll free: +1 800 387 8898 Option 3, or Direct Dial: +1 905 813 9900 Ext. 1999 Option 3.F

Strany 163 - ÌFQ9C2>Î

POWERSCAN™ D8330/M8300 38 4.9 USB READER CONFIGURATION The USB interface is available for PowerScan™ D8330, BC-80x0 and C-8000 devices and is compa

Strany 164

CONFIGURATION 39 USB USB-KBD Ì$+UA03$-:Î USB-KBD-ALT-MODE Ì$+UA04$-@Î USB-KBD-APPLE Ì$+UA05$-FÎ USB-COM* Ì$+UA02$-4Î USB-IBM-Table Top

Strany 165

POWERSCAN™ D8330/M8300 40 4.10 CHANGING DEFAULT SETTINGS Once your reader is setup, you can change the default parameters to meet your applicati

Strany 166 - 5.4.5 Time Stamping Format

41 RS-232 PARAMETERS All PowerScan™ D8330 Series readers + PowerScan™ M8300/BC-80X0 configurations only  Baud Rate Parity Data Bits  Stop

Strany 167 - 5.5.2 Enter Sleep Timeout

Enter Configuration Exit and Save Ì$+;Î RS-232 Ì$-?Î 42 BAUD RATE 300 baud ÌCD1XÎ 600 baud 1200 baud ÌCD2[Î ÌCD3^Î 2400 baud 4800

Strany 168 - 5.6.4 Reads per Cycle

Enter Configuration Exit and Save Ì$+;Î RS-232 Ì$-?Î 43 DATA BITS 7 bits ÌCA0OÎ  8 bits 9 bits ÌCA1RÎ ÌCA2UÎ STOP BITS  1 stop bit ÌCB

Strany 169 - 5.7.2 Overflow Control

Enter Configuration Exit and Save Ì$+;Î RS-232 Ì$-?Î 44 ACK/NACK PROTOCOL  disable ÌER0sÎ enable ÌER1vÎ See section 5.1.2 for details,

Strany 170 - 5.8.1 Match Conditions

Enter Configuration Exit and Save Ì$+;Î RS-232 Ì$-?Î 45 RX TIMEOUT timeout control in reception from Host ÌCL5Î Read 2 numbers from the table whe

Strany 171 - 5.9.3 Power-Off Timeout

46 USB PARAMETERS  USB-COMHandshaking, Ack/Nack protocol, FIFO, Inter-character delay, Rx timeout, Serial trigger lock  USB-KBDKeyboard natio

Strany 172 - 5.9.4 Transmission Mode

Enter Configuration Exit and Save Ì$+;Î USB-COM Ì$-?Î 47 HANDSHAKING  disable ÌCE0WÎ hardware (RTS/CTS) software (XON/XOFF) ÌCE1ZÎ ÌCE2]Î

Strany 174 - M8300 only)

Enter Configuration Exit and Save Ì$+;Î USB-COM Ì$-?Î 48 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbe

Strany 175 - 5.10.1 Display Mode

Enter ConfiguratioN Exit and Save Ì$+;Î USB-KBD Ì$-?Î 49 KEYBOARD NATIONALITY Not Available for USB-KBD-ALT-MODE Interface This parameter default v

Strany 176

Enter Configuration Exit and Save Ì$+;Î USB-KBD Ì$-?Î 50 The Japanese and Eastern Block Keyboard Nationality selections are valid only for IBM AT

Strany 177 - Ì#+CODEÂÎ

Enter ConfiguratioN Exit and Save Ì$+;Î USB-KBD Ì$-?Î 51 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers

Strany 178 - Ì$+ZZ0$-*Î

52 WEDGE PARAMETERS All PowerScan™D8330 Series readers+ PowerScan™ M8300/BC-80X0 configurations only  Keyboard Nationality Caps Lock Caps L

Strany 179 - Ì$+ZZ2$-4Î

Enter Configuration Exit and Save Ì$+;Î WEDGE Ì$-?Î 53 KEYBOARD NATIONALITY Belgian ÌFJ7yÎ English (UK) French ÌFJ4pÎ ÌFJ2jÎ German Itali

Strany 180 - Copy Configuration

Enter Configuration Exit and Save Ì$+;Î WEDGE Ì$-?Î 54 The Japanese and Eastern Block Keyboard Nationality selections are valid only for IBM AT co

Strany 181

Enter Configuration Exit and Save Ì$+;Î WEDGE Ì$-?Î 55 CAPS LOCK AUTO-RECOGNITION (IBM AT COMPATIBLE ONLY) disable ÌFP0pÎ  enable ÌFP1sÎ NU

Strany 182 - Ì$+RN2$-SÎ

Enter Configuration Exit and Save Ì$+;Î WEDGE Ì$-?Î 56 INTER-CODE DELAY delay between codes transmitted to Host ÌFG.Î Read 2 numbers from the ta

Strany 183 - 6 MESSAGE FORMATTING

Enter Configuration Exit and Save Ì$+;Î WEDGE Ì$-?Î 57 Some ASCII characters may be missing, depending on the keyboard type. These are generally pa

Strany 184 - D8330/M8300

TABLE OF CONTENTS i CONTENTS 1 INTRODUCTION ...

Strany 185 - 6.2.3 Clearing Display

58 PEN EMULATION All PowerScan™ D8330 Series readers + PowerScan™ M8300/BC-80X0 configurations only  Operating Mode Minimum Output Pulse Co

Strany 186 - 6.2.5 Setting RTC

PEN EMULATION 59 The following operating mode parameters are complete commands and do not require reading the Enter and Exit configuration code

Strany 187 - [Terminator]

Enter Configuration Exit and Save Ì$+;Î PEN EMULATION Ì$-?Î 60 MINIMUM OUTPUT PULSE 200 s low resolution code emulation high resolution co

Strany 188 - 7 TECHNICAL FEATURES

Enter Configuration Exit and Save Connfiguration Ì$+;Î PEN EMULATION Ì$-?Î 61 CONVERSION TO CODE 39 (D8330 SERIES ONLY)  disable conversion to Co

Strany 189 - 7.2 POWERSCAN

Enter Configuration Exit and Save Ì$+;Î PEN EMULATION Ì$-?Î 62 OUTPUT LEVEL  normal ÌDD0VÎ (white = logic level 0) inverted ÌDD1YÎ (white =

Strany 190 - 7.3 BC-80X0 / C-8000

63 NETWORK PARAMETERS BC-8060 model configurations only  RS-485 Network Network Baud Rate Slave Address Range Network Warning Message Rece

Strany 191 - 7.5 STATUS INDICATORS

Enter Configuration Exit and Save Ì$+;Î NETWORK PARAMETERS Ì$-?Î 64 RS-485 NETWORK  disable RS-485 network ÌRZ0)Î enable RS-485 slave enab

Strany 192

Enter Configuration Exit and Save Ì$+;Î NETWORK PARAMETERS Ì$-?Î 65 SLAVE ADDRESS RANGE First Address ÌJB(Î Read the code above and the four-digi

Strany 193

Enter Configuration Exit and Save Ì$+;Î NETWORK PARAMETERS Ì$-?Î 66 MASTER CRADLE HEADER  no header ÌJA00/Î one character header two cha

Strany 194 - 7.6 Reading Tables

Enter Configuration Exit and Save Ì$+;Î NETWORK PARAMETERS Ì$-?Î 67 MASTER CRADLE TERMINATOR  no terminator ÌJA102Î one character terminator

Strany 195 - A HOST CONFIGURATION STRINGS

POWERSCAN™ D8330/M8300 ii 4.5.1 Using Multiple M-Series Readers with the Same Cradle ... 29 4.5.2 PowerScan™ M8300/STAR-Mo

Strany 196

68 DATA FORMAT NOT FOR PEN INTERFACES  Code Identifier Custom Code Identifier Header Terminator Special Keys Field Adjustment  Fiel

Strany 197 - (100 ms)

DATA FORMAT 69 CODE IDENTIFIER TABLE CODE AIM STANDARD MANUFACTURER STANDARD Custom 2/5 interleaved ] I y N 2/5 industrial ] X y P 2/5 n

Strany 198

Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 70 CODE IDENTIFIER  disable ÌEB0SÎ Manufacturer standard AIM standard ÌEB1VÎ ÌEB

Strany 199

Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 71 HEADER no header ÌEA00*Î one character header two character header ÌEA01.Î 

Strany 200 - PEN (continued)

Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 72 TERMINATOR no terminator ÌEA10-Î one character terminator two character ter

Strany 201

Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 73 SPECIAL KEYS Available only for Wedge IBM AT-PS/2 and USB-KBD Interfaces It is nece

Strany 202 - DATA FORMAT (continued)

Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 74 FIELD ADJUSTMENT  disable field adjustment ÌEF0[Î Field adjustment allows a number

Strany 203 - READING PARAMETERS

Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 75 FIELD ADJUSTMENT CHARACTER  Read the field adjustment character code: field adjust

Strany 204

Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 76 CHARACTER REPLACEMENT  disable character replacement ÌEO0mÎ This parameter allows

Strany 205

Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 77 Example: The following strings define: 1. First Character Replacement: substitution in

Strany 206 - CODE SELECTION (continued)

TABLE OF CONTENTS iii 5.4.6 Time Stamping Delimiter ... 154 5.5 Powe

Strany 207

Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 78 ADDRESS STAMPING (M8300 SERIES ONLY)  disable reader address stamping ÌRU0ÊÎ 

Strany 208

Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 79 TIME STAMPING (M8300 SERIES ONLY)  disable ÌIL0kÎ hour/minutes/seconds month/day/

Strany 209 - B CODE IDENTIFIER TABLE

80 POWER SAVE  Sleep State Enter Sleep Timeout Read the Enter Configuration code ONCE, available at the top of each page.

Strany 210

Enter Configuration Exit and Save Ì$+;Î POWER SAVE Ì$-?Î 81 SLEEP STATE  disable ÌBQ0nÎ enable ÌBQ1qÎ See section 5.5.1 for details. For M8

Strany 211

82 READING PARAMETERS  Trigger Type Trigger Signal Trigger Click Trigger-off Timeout Flash Mode Reads per Cycle Safety Time Beeper

Strany 212 - C HEX AND NUMERIC TABLE

Enter Configuration Exit and Save Ì$+;Î READING PARAMETERS Ì$-?Î 83 TRIGGER TYPE  hardware trigger ÌBK1eÎ Restores TRIGGER MODE software trigge

Strany 213

Enter Configuration Exit and Save Ì$+;Î READING PARAMETERS Ì$-?Î 84 TRIGGER-OFF TIMEOUT trigger-off timeout ÌBD$Î Read 2 numbers in the range 0

Strany 214 - HEX/NUMERIC BAR CODES

Enter Configuration Exit and Save Ì$+;Î READING PARAMETERS Ì$-?Î 85 SAFETY TIME safety time ÌBE&Î Limits same code consecutive reading. Read

Strany 215

Enter Configuration Exit and Save Ì$+;Î READING PARAMETERS Ì$-?Î 86 BEEPER TONE tone 1 ÌBH0\Î  tone 2 tone 3 ÌBH1_Î ÌBH2bÎ tone 4 ÌBH3e

Strany 216

Enter Configuration Exit and Save Ì$+;Î READING PARAMETERS Ì$-?Î 87 GOOD READ SPOT DURATION disable ÌBV0xÎ short  medium ÌBV1{Î ÌBV2~Î