Chapter 6: Settings
Manage Triggers
Psion EP10 Hand-Held Computer User Manual
148
Double-Click
When a key is pressed and released, then pressed again within the configured time (between 0 to 1000 mil-
liseconds), a double-click occurs. See also “Trigger Press Type” on page 149.
Show All Modules
By default, the trigger mapping list only shows active mappings. Mappings for drivers or applications that
are not currently active are not normally displayed. By checking this checkbox, all mappings, both active
and inactive, are displayed.
Add
Tapping this button brings up the Add mapping dialog (see below), so that you can add new trigger map-
pings.
Edit
Tapping this button brings up the Edit mapping dialog, so that you can edit existing trigger mappings.
Remove
Tapping this button removes an existing mapping.
OK
The OK button in the Manage Triggers screen saves all changes made. If the [ESC] key is pressed, all
changes are discarded.
6.10.12.1.1 Add and Edit Trigger Mapping
•Tap on Add to add a new trigger map, or tap on Edit to edit an existing trigger map.
Trigger Key
This drop-down list allows you to specify the source of the trigger events, such as the Grip Trigger, Left
Scan, etc., for the trigger module selected.
Important: It is not possible to have two or more identical mappings — for example [F1] cannot be
mapped to the Non-Decoded Scanner twice — even if the trigger type is different.
A keyboard key that is used as a trigger source will no longer generate key data or
perform its normal function. For example, if the space button is used as a trigger
source, it will not be able to send space characters to applications.
Note: It is possible to map the same source to different modules (trigger consumers) – for example, to
both the Imager and Non-Decoded Scanner. If so, both devices/operations will occur simultane-
ously. This is not recommended in most cases, especially with devices such as Imagers.
It is also possible to map different sources to the same module (trigger consumer).